To check and adjust the bias voltage of the 300B tubes, simply follow the following procedures:
  1. Making sure that the power switch is in the OFF position.


  2. Install all the tubes to the corresponding sockets using a gentle rocking motion.


  3. Connect your speaker leads, input cable and power cord to each amplifier.


  4. Turn ON the amplifier.


  5. Turn on the multimeter. Select the section for measuring up to 20V DC. Attach and secure the negative test lead to the chassis or to the binding post.


  6. Insert the positive test lead into the bias test point marked as "300B - V1".


  7. Carefully insert a long-handled slotted screwdriver into the bias adjustment pot marked as "300B - V1". Slowly rotate the screwdriver to adjust the bias voltage until it reaches 0.55V.


  8. Repeat steps 6 and 7 to adjust the bias voltage for the other 300B tube using bias test point marked as "300B - V2" and bias adjustment pot marked as "300B - V2". You will need to go back and forth a few times until both of the 300B tubes are properly biased.


  9. Once you have finished biasing the two 300B tubes, wait a few minutes and recheck the settings again.


  10. Repeat these procedures to adjust the bias voltage for the 300B tubes on the other channel of the amplifier.


  11. The CA-3330 mono blocks power amplifier is now ready to use.
 